Q. 48 A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250rpm. The induced armature voltage is
(A) 96 V
(B) 192 V
(C) 384 V
(D) 768 V
Answer:(C)
Explanation: