Q. 40 Consider the two bus power system network with given loads as shown in the figure. All the values shownin the figure are in per unit. The reactive power supplied by generator respectively. The per unit values of and line reactive power loss loss respectively are
(A) 5.00, 12.68, 2.68
(B) 6.34, 10.00, 1.34
(C) 6.34, 11.34, 2.68
(D) 5.00, 11.34, 1.34
Answer:(C)
Explanation: