Q. 35 In a constant V/f control of induction motor, the ratio V/f is maintained
constant from 0 to base frequency, where V is the voltage applied to the motor
at fundamental frequency f . Which of the following statements relating to low
frequency operation of the motor is TRUE ?
(A) At low frequency, the stator flux increases from its rated value.
(B) At low frequency, the stator flux decreases from its rated value.
(C) At low frequency, the motor saturates.
(D) At low frequency, the stator flux remains unchanged at its rated value.
Answer:(B)
Explanation: