Q. 47 A strain gauge forms one arm of the bridge shown in the figure below and has a nominal resistance without any load as Other bridge resistances are . The maximum permissible current through the strain gauge is 20 mA. During certain measurement when the bridge is excited by maximum permissible voltage and the strain gauge resistance is increased by 1% over the nominal value, the output voltage in mV is
(A) 56.02
(B) 40.83
(C) 29.85
(D) 10.02
Answer:(C)
Explanation:
Not Required.