Gate EE-2004 Question Paper With Solutions

Q. 24  A dc potentiometer is designed to measure up to about 2 V with a slide wire of
800 mm. A standard cell of emf 1.18 V obtains balance at 600 mm. A test cell
is seen to obtain balance at 680 mm. The emf of the test cell is

(A) 1.00 V

(B) 1.34 V

(C) 1.50 V

(D) 1.70 V

Answer:(B)

Explanation:

Gate EE-2004 Question Paper With Solutions

Learn More:   Gate CS-2017-1 Question Paper With Solutions

LEAVE A REPLY

Please enter your comment!
Please enter your name here